Product Name:
Glass Measuring Cylinder
Product Type:
5–2000ml
Product Material:
High borosilicate glass
Product Introduction:
The graduated cylinder is a tall, cylindrical container with a spout on one side of the top for easy pouring. The bottom has a wide base to maintain stability. The walls of the cylinder are marked with graduations from bottom to top. When reading the measurement, the experimenter should ensure that their line of sight is level with the lowest point of the liquid's meniscus.
Product Show
Made of BORO3.3 high borosilicate glass, resistant to high temperatures and corrosion.
The color is clean and transparent, and the simple opening is smooth without gnaw marks.
The overflow outlet (mold forming) allows smooth and controllable liquid flow.

Measuring Cylinder Round Base Show
Measuring Cylinder Hexagon Base Show
Measuring Cylinder With Glass Stopper Show
Measuring Cylinder With Plastic Hexagon Base & Guard Ring Show
Product Details Show
Size Show




































Glass Measuring Cylinder Specs
| Description | Picture | Spec (ml) | Base Diameter (mm) | Outer Diameter (mm) | Height (mm) | Weight (g) |
|---|---|---|---|---|---|---|
| Measuring Cylinder, Round Base |
|
5ml | 37 | 14 | 123 | 27 |
| 10ml | 40 | 16 | 151 | 37 | ||
| 25ml | 47 | 20 | 166 | 43 | ||
| 50ml | 60 | 26 | 198 | 75 | ||
| 100ml | 63 | 31 | 260 | 112 | ||
| 250ml | 80 | 42 | 305 | 201 | ||
| 500ml | 93 | 56 | 364 | 322 | ||
| 1000ml | 109 | 64 | 452 | 470 | ||
| 2000ml | 140 | 85 | 520 | 731 | ||
| Measuring Cylinder, Hexagon Base |
|
5ml | 49 | 14 | 122 | 33 |
| 10ml | 50 | 15 | 140 | 34 | ||
| 25ml | 60 | 22 | 168 | 56 | ||
| 50ml | 65 | 27 | 197 | 90 | ||
| 100ml | 73 | 33 | 246 | 150 | ||
| 250ml | 102 | 42 | 302 | 261 | ||
| 500ml | 114 | 55 | 353 | 356 | ||
| 1000ml | 133 | 67 | 455 | 589 | ||
| 2000ml | 169 | 90 | 520 | 1134 | ||
| Measuring Cylinder With Glass Stopper |
|
5ml | 39 | 9 | 140 | 33 |
| 10ml | 40 | 15 | 170 | 35 | ||
| 25ml | 46 | 22 | 212 | 75 | ||
| 50ml | 54 | 25 | 244 | 90 | ||
| 100ml | 63 | 32 | 290 | 151 | ||
| 250ml | 77 | 42 | 375 | 273 | ||
| 500ml | 97 | 56 | 422 | 400 | ||
| 1000ml | 110 | 64 | 513 | 564 | ||
| 2000ml | 141 | 90 | 590 | 1049 | ||
| Measuring Cylinder With Plastic Hexagon Base Guard Ring |
|
5ml | 56 | 9 | 117 | 28 |
| 10ml | 57 | 16 | 150 | 38 | ||
| 25ml | 63 | 22 | 161 | 54 | ||
| 50ml | 65 | 27 | 198 | 81 | ||
| 100ml | 75 | 33 | 247 | 116 | ||
| 250ml | 102 | 42 | 314 | 202 | ||
| 500ml | 110 | 55 | 355 | 315 | ||
| 1000ml | 122 | 66 | 441 | 496 | ||
| 2000ml | 179 | 90 | 500 | 853 |
Precautions
- When pouring liquid into a graduated cylinder, tilt the cylinder slightly and keep the mouth of the bottle close to the cylinder's opening. When the amount to be added is slightly less than the required volume, switch to a dropper to add the liquid until the desired amount is reached.
- After injecting the liquid, wait 1 - 2 minutes for the liquid adhering to the inner wall to flow down, and then read the scale value. Otherwise, the measured value will be underestimated.
- Do not dilute or prepare solutions in a graduated cylinder; do not heat the graduated cylinder.
- Do not carry out chemical reactions in a graduated cylinder: it may damage the cylinder and sometimes even cause danger.
- Do not leave the graduated cylinder with chemicals for long periods to avoid contamination by dust and evaporation of water from the solution.
- Do not use scouring powder to clean to avoid scratching the markings.
Frequently Asked Questions (FAQ)
What is the material of the Glass Measuring Cylinder?
The Glass Measuring Cylinder is made of high-quality BORO3.3 high borosilicate glass, which is highly resistant to thermal shock, high temperatures, and chemical corrosion.
How do you read the scale measurement correctly?
When reading the measurement, ensure that your line of sight is completely level with the lowest point of the liquid's meniscus. Also, wait 1 to 2 minutes after pouring for the liquid adhering to the inner wall to flow down.
Can I heat or perform chemical reactions in the graduated cylinder?
No, you should never heat the graduated cylinder, dilute or prepare solutions, or conduct chemical reactions inside it. Doing so can cause glass breakage, damage the scale, or pose a physical hazard.
What types of bases are available for these measuring cylinders?
We offer multiple stable base designs, including a round base, a hexagon base, and a plastic hexagon base with a guard ring, to suit different laboratory stability preferences.
How should I clean the glass measuring cylinder?
Wash the cylinder gently using standard laboratory detergents. Do not use scouring powder or abrasive materials to scrub the cylinder, as they can scratch the glass surface and wear off the printed scale graduations.