0102030405
Borosilicate Glass Measuring Cylinder - Reliable Lab Equipment from China Suppliers & Factory, 5ml-2000ml
Glass Measuring Cylinder
High borosilicate glass
Stable base
Clear scale
Measuring Cylinder Round Base
Measuring Cylinder Hexagon Base
Measuring Cylinder With Glass Stopper
Measuring Cylinder With Plastic Hexagon Base & Guard Ring
Product Name: Glass Measuring Cylinder
Product Type: 5–2000ml
Product Material: High borosilicate glass
Product Introduction: The graduated cylinder is a tall, cylindrical container with a spout on one side of the top for easy pouring. The bottom has a wide base to maintain stability. The walls of the cylinder are marked with graduations from bottom to top. When reading the measurement, the experimenter should ensure that their line of sight is level with the lowest point of the liquid's meniscus.
Product Show
Made of BORO3.3 high borosilicate glass, resistant to high temperatures and corrosion.
The color is clean and transparent, and the simple opening is smooth without gnaw marks.
The overflow outlet (mold forming) allows smooth and controllable liquid flow.
Measuring Cylinder Round Base Show
Measuring Cylinder Hexagon Base Show
Measuring Cylinder With Glass Stopper Show
Measuring Cylinder With Plastic Hexagon Base & Guard Ring Show
Product Details Show
Size Show




































Glass Measuring Cylinder Specs
| Description | Picture | Spec (ml) | Base Diameter (mm) | Outer Diameter (mm) | Height (mm) | Weight (g) |
|---|---|---|---|---|---|---|
| Measuring Cylinder, Round Base |
|
5ml | 37 | 14 | 123 | 27 |
| 10ml | 40 | 16 | 151 | 37 | ||
| 25ml | 47 | 20 | 166 | 43 | ||
| 50ml | 60 | 26 | 198 | 75 | ||
| 100ml | 63 | 31 | 260 | 112 | ||
| 250ml | 80 | 42 | 305 | 201 | ||
| 500ml | 93 | 56 | 364 | 322 | ||
| 1000ml | 109 | 64 | 452 | 470 | ||
| 2000ml | 140 | 85 | 520 | 731 | ||
| Measuring Cylinder, Hexagon Base |
|
5ml | 49 | 14 | 122 | 33 |
| 10ml | 50 | 15 | 140 | 34 | ||
| 25ml | 60 | 22 | 168 | 56 | ||
| 50ml | 65 | 27 | 197 | 90 | ||
| 100ml | 73 | 33 | 246 | 150 | ||
| 250ml | 102 | 42 | 302 | 261 | ||
| 500ml | 114 | 55 | 353 | 356 | ||
| 1000ml | 133 | 67 | 455 | 589 | ||
| 2000ml | 169 | 90 | 520 | 1134 | ||
| Measuring Cylinder With Glass Stopper |
|
5ml | 39 | 9 | 140 | 33 |
| 10ml | 40 | 15 | 170 | 35 | ||
| 25ml | 46 | 22 | 212 | 75 | ||
| 50ml | 54 | 25 | 244 | 90 | ||
| 100ml | 63 | 32 | 290 | 151 | ||
| 250ml | 77 | 42 | 375 | 273 | ||
| 500ml | 97 | 56 | 422 | 400 | ||
| 1000ml | 110 | 64 | 513 | 564 | ||
| 2000ml | 141 | 90 | 590 | 1049 | ||
| Measuring Cylinder With Plastic Hexagon Base Guard Ring |
|
5ml | 56 | 9 | 117 | 28 |
| 10ml | 57 | 16 | 150 | 38 | ||
| 25ml | 63 | 22 | 161 | 54 | ||
| 50ml | 65 | 27 | 198 | 81 | ||
| 100ml | 75 | 33 | 247 | 116 | ||
| 250ml | 102 | 42 | 314 | 202 | ||
| 500ml | 110 | 55 | 355 | 315 | ||
| 1000ml | 122 | 66 | 441 | 496 | ||
| 2000ml | 179 | 90 | 500 | 853 |
Precautions
- 1. When pouring liquid into a graduated cylinder, tilt the cylinder slightly and keep the mouth of the bottle close to the cylinder's opening. When the amount to be added is slightly less than the required volume, switch to a dropper to add the liquid until the desired amount is reached.
- 2. After injecting the liquid, wait 1 - 2 minutes for the liquid adhering to the inner wall to flow down, and then read the scale value. Otherwise, the measured value will be underestimated.
- 3. Do not dilute or prepare solutions in a graduated cylinder; do not heat the graduated cylinder.
- 4. Do not carry out chemical reactions in a graduated cylinder: it may damage the cylinder and sometimes even cause danger.
- 5. Do not leave the graduated cylinder with chemicals for long periods to avoid contamination by dust and evaporation of water from the solution.
- 6. Do not use scouring powder to clean to avoid scratching the markings.
Frequently Asked Questions (FAQ)
What are the main applications of a glass measuring cylinder?
Glass measuring cylinders are primarily used in laboratory settings to measure precise volumes of liquids for chemical experiments, biological testing, and quality control processes.
Can I heat a glass measuring cylinder directly?
No, measuring cylinders should never be heated or used to prepare hot solutions. Thermal expansion can distort the calibrated volumetric markings, reducing measurement accuracy or causing the glass to break.
Why is high borosilicate glass used for these cylinders?
High borosilicate glass (specifically BORO 3.3) provides exceptional thermal shock resistance, low thermal expansion coefficient, and high chemical resistance against acids, alkalis, and organic solvents.
How do you read the liquid volume in a cylinder accurately?
Place the cylinder on a flat, level surface. Bring your eyes to the exact level of the liquid surface, and read the scale value aligned with the lowest point of the liquid's meniscus.
What is the advantage of a hexagon base over a round base?
A hexagon base provides enhanced stability and prevents the measuring cylinder from rolling off the workbench if it is accidentally knocked over, reducing the risk of breakage.