contact us
Leave Your Message

High-Quality PTFE High Pressure Digestion Tank from China Suppliers & Factory for COD Microwave Applications

,

PTFE Digestion Tank:

,

Discover our high-quality PTFE Digestion Tanks, designed for optimal performance in microwave COD digestion applications. Made from premium PTFE (Teflon), these tanks provide exceptional durability and chemical resistance, making them ideal for laboratory and chemical uses.

,

Product Specifications:
, - Material: PTFE/Teflon
, - Color: Pure white
, - Volume Options: 10ml, 30ml, 50ml, 100ml, 200ml (Custom sizes available)
, - Temperature Range: -196℃ to +250℃
, - Packaging: Secure export packaging for safe delivery

,

Key Features:
, Crafted from virgin purity PTFE material for reliable performance.
, Smooth surface finish with no burrs or marks, ensuring easy cleaning and handling.
, Designed for duplication, meeting the needs of various laboratory applications.

,

Safety Precautions:
, ***Maintain temperature below 200°C and pressure below 0.4Mpa.
, ***Do not fully close the inner cap while heating to prevent excessive pressure buildup inside the tank.

,

As a leading supplier and factory in China, we are committed to providing high-quality lab equipment that meets international standards. Trust our PTFE Digestion Tanks for your laboratory needs.

,

    PTFE COD Digestion Tank

    • High temperature resistant
    • High voltage resistant
    • With explosion-proof safety cover
    PTFE COD Digestion Tank 1
    PTFE COD Digestion Tank 3
    PTFE COD Digestion Tank 2
    PTFE COD Digestion Tank Detail
    PTFE COD Digestion Tank
    Product Name: PTFE COD Digestion Tank
    Product Type: 30-200ml
    Product Material: PTFE
    Product Introduction: The PTFE COD digestion vessel is used to safely digest water samples under high temperature and high pressure conditions for the determination of Chemical Oxygen Demand (COD). It is suitable for water quality monitoring and for the pretreatment of various samples, including industrial wastewater, domestic sewage, and surface water, before COD testing.

    Product Show

    • Reserved explosion-proof holes, high safety
    • The lid has a threaded design, providing good sealing.
    • Thickened inner wall for a longer service life.
    Product Show 7539
    Product Show 7554
    Product Show 7441
    Product Show 7495
    Product Show 7524

    Product Details Show

    Details Show 4
    Details Show 7524
    Details Show 7496
    Details Show 7446

    Size Show

    30ml Size
    50ml Size
    60ml Size
    100ml Size
    200ml Size

    PTFE COD Digestion Tank Specs

    Description Picture Spec (ml) Bottle Outer Diameter (mm) Lid Outer Diameter (mm) Mouth Inner Diameter (mm) Height (mm) Wall Thickness (mm) Weight (g)
    PTFE COD Digestion Tank PTFE Spec Drawing 30 38 46 25 120 7 219
    50 47 55 30 120 9 351
    60 48 56 30 133 9 378
    100 58 71 40 135 9 559
    200 68 80 50 157 9 747

    Product Features

    • 1 Samples: The reagent should not exceed 2/3 of the container's volume. Samples with high chlorine or high organic content require pretreatment.
    • 2 Temperature resistance ≤200° C. Strictly control the temperature and the heating rate according to regulations, and do not exceed the temperature limit.
    • 3 After digestion, allow to cool naturally to room temperature. Release pressure before opening the lid, and do not operate while hot.
    • 4 Only for use in compatible systems. Avoid direct contact of highly corrosive reagents with the container wall, and do not scrape with hard tools.
    • 5 Inspect the container and seals before and after use. After cleaning, dry and store with the seal intact.

    Frequently Asked Questions

    What are the primary safety features of the PTFE COD Digestion Tank?
    The digestion tank is designed with reserved explosion-proof holes, high voltage resistance, and an explosion-proof safety cover to ensure safe sample digestion under high-pressure conditions.
    What is the maximum operating temperature for the PTFE COD Digestion Tank?
    The digestion tank has a temperature resistance of ≤200°C. It is important to strictly control the temperature and heating rate according to regulations and not exceed this limit.
    What size specifications are available for this product?
    The product is available in capacities ranging from 30ml to 200ml, with specific sizes including 30ml, 50ml, 60ml, 100ml, and 200ml.
    How should the digestion tank be opened after heating?
    After digestion, allow the tank to cool naturally to room temperature. You must release the internal pressure before opening the lid. Never attempt to open or operate the vessel while it is still hot.
    What is the limit for reagent volume inside the container?
    Reagents filled inside the PTFE COD Digestion Tank should not exceed 2/3 of the container's total volume.
    What samples are suitable for pretreatment with this digestion tank?
    It is suitable for the pretreatment of industrial wastewater, domestic sewage, and surface water before Chemical Oxygen Demand (COD) testing. Samples with high chlorine or high organic content require proper pretreatment.